Parameter
Data Collection: Test Data every 11 seconds record an average blood glucose level every 3 minutes
High and low blood sugar reminder: Can be set the interval by yourself, and it will prompt if it is higher or lower than the set interval.
Power Supply: Button Battery
Data Storage method: stored in the wireless transmitter
Data Transmission Method: Bluetooth 4.0
Size: 44.2*28*12.5 mm
Valid range of Glucose concentration Test: 1.7 mmol/l-25mmol/l
Electrode Depth: 03mm±0.07mm
Effective Working Time: Not less than 120 hours
Accuracy:RE%≤12%
Wearing Part: Recommended to be worn on the upper arm, and directly implanted under the skin without auxiliary tools

Product: Continuous Glucose Monitor Meter CGM S1

High Light: Dynamic Glucose Monitoring System help you build a blood glucose management paltform inside and outside the hospital.

Features
1.Real-time dynamic glucose monitoring system high and low blood sugar prompt.
Promote HbAIc compliance, without increasing the risk of hypoglycemia. Correct in time to avoid hypoglycemia.
Medical Evidence shows that blood sugar management under the guidance of real-time CGM can achieve better blood sugar lowering effects. And the decrease of glycosylated hemoglobin is positively correlated with the frequency of use of glucose dynamic sensor. That is, frequent real-time CGM, better blood sugar control.
2.Dynamic blood glucose monitoring system can visually display blood glucose fluctuations after meals.
Help patients reduce the percentage of high and low blood sugar time.
One value for 3 minutes, accurately capture the peak blood glucose after a meals
3. Miniature size high sensitivity dynamic glucose sensor   
Length is only 4 mm, Diameter 0.2 mm
The volume is only 1/4 of similar products, the contact area is eight times that of similar products
The original free-hand implantation technology does not requie any auxiliary equipment, and the whole wearing process is almost paintless.
Integrated design of sensor and transmitter

4.Clinical accuracy of dynamic glucose monitoring system

5.​Application of pump therapy.

6.Discovery of hypoglycemia that can not be captured

Unexplained severe hypoglycemia
Asymptomatic hypoglycemia
Repeated Hypoglycemia
Nocturnal hypoglycemia

7.Found occult hyperglycemia
High blood sugar fluctuations
Unexplained hyperglycemia
Fasting hyperglycemia

8.Discover the indistinguishable dawn blood sugar
SMBG results are good, but HBA1c is always not to standard
Out of fear of hypoglycemia, patients who deliberately maintain hyperglycemia